Vitrek White Papers
Articles
Vitrek in the News…
Press Release: Vitrek, LLC Expands Industry-Leading MTI PBS line to include the PBS eXpress™, a Portable Engine Balancing System for Business and Regional Jets

Vitrek, LLC Expands Industry-Leading MTI PBS line to include the PBS eXpress™, a Portable Engine Balancing System for Business and Regional Jets
Lightweight, portable system utilizes proven PBS technology for fast, highly accurate rebalancing of small-frame turbofan and turboprop engines
Lockport, IL—October 17, 2024— Vitrek, LLC, a U.S.-based manufacturer of advanced test and measurement equipment, introduces the enhanced PBS eXpress aircraft engine vibration analysis and balancing system. Designed to optimize engine performance in the small-frame turbofan and turboprop engines used in regional, business and smaller military jets, the PBS eXpress minimizes down-time and fuel costs by eliminating guesswork.
It features advanced algorithms based on commonly used engines to translate vibration and speed measurements into accurate balancing solutions. Available in rack mount as well as portable versions for on-runway testing, the system features intuitive setup and easy-to-operate visualization tools like vibration surveys, exportable data and PDF reporting. Supported propulsion systems include the most popular small-frame engines and APUs from major OEMs such as Honeywell, Rolls-Royce, P&W Canada, and Williams International.
The PBS eXpress features the same industry-leading technology developed for the PBS-4100+ family of balancing products used world-wide to support the larger frame engines on leading airlines and military jets.
Market-leading features of the portable PBS eXpress include:
- Modern Interface – Color touchscreen operates the entire Windows-based user interface.
- Extreme Simplicity – The Trim Balance Wizard streamlines the diagnosic process with simple-to-follow steps.
- Advanced Functionality – Rapidly calculates optimized engine balancing solutions accounting for existing weights on the engine and generates detailed “before and after” PDF reports.
- Convenience – Lightweight and portable system operates 6-plus hours between battery charges.
- Ease of Migration – Usable with common cables, pickups, and sensors.
Gary Schafer, President of Vitrek, LLC, said, “The PBS eXpress offers many of the advanced features found on the most sophisticated engine balancing systems – but with a price point and form factor optimized for MRO organizations and operators who maintain small-to-mid-sized corporate and regional jets.” He continued, “The PBS eXpress’s industry leading intuitive user-interface enables operators to perform vibration analysis and engine rotor balancing, with minimal training.”
The PBS eXpress will be on display at the NBAA-BACE Show at the Las Vegas Convention Center, West Hall in Las Vegas on Oct. 22-24. The product will be shown along with the PBS-4100+ for large frame jet engines and the portable1510A which allows technicians to bring a laboratory-grade precision function generator directly to the flight line.
About Vitrek and MTI Instruments
In 2022 MTI Instruments was purchased by Vitrek, LLC, a US-based designer and manufacturer of test and measurement tools. The Vitrek family of brands also includes the MTI line of capacitive measurement solutions for semi-conductor wafers and high-precision film products; the GaGe digitizer cards as well as the broad line of precision voltage generators and hi-pot testers that have long been offered by Vitrek.
Vitrek products are widely used not only in the aerospace industries, but the electrical vehicle, medical, research and development markets, as well as by a wide variety of electrical products makers.
Did You Know? GaGe Digitizers in Military & Aerospace Applications

Introduction
High-speed digitizers are indispensable tools in the military and aerospace industries, revolutionizing the way data is captured, processed, and analyzed. These advanced devices enable precise measurement and real-time monitoring of complex systems, from radar and communication systems to electronic warfare and avionics. By converting analog signals into high-resolution digital data at unprecedented speeds, high-speed digitizers enhance the accuracy and efficiency of critical operations, ensuring superior performance and reliability in some of the most unique applications.
Unlocking the Skies: Advanced Drone Detection with X-Band Radar
With the increasing use of drones across various sectors, there’s a growing need for effective drone detection systems to address security and safety concerns. Radar technology emerges as a promising solution due to its reliability under diverse conditions.
Challenge: Detecting small commercial drones poses a significant challenge for radar systems due to their low radar cross-section and slow flight dynamics. Traditional radar setups struggle to distinguish drone echoes from background clutter effectively.
How the GaGe Digitizer was used: The solution introduces RAD-DAR, a radar demonstrator system designed for quick deployment and efficient detection of small drones. Utilizing an 8-channel digital array and sophisticated signal processing techniques, the system captures and analyzes radar echoes to identify and track drones accurately.
The RAD-DAR system demonstrates impressive capabilities, detecting a DJI Phantom 4 drone at ranges of up to 2 km with strong range-speed association. By leveraging advanced processing algorithms, the system achieves robust detection performance even in cluttered environments. Additionally, you may read the full application paper which presents a statistical analysis of drone radar cross-sections, laying the groundwork for effective drone classification and tracking algorithms.
Revolutionizing Machine Health: Advanced Sensor for Real-Time Lubricant Monitoring
When there is a need for real-time health monitoring of rotating or reciprocal machinery, the goal is to prevent costly shutdowns. This is done by detecting potential failures before they occur. A key point is monitoring lubricating oil conditions which are essential for assessing machine health.
Challenge: Traditional methods require machine shutdowns for inspection, leading to downtime and potential catastrophic failures. Current sensors lack sensitivity and struggle with high data volume and processing time, making real-time monitoring impractical.
How the GaGe Digitizer was used: This innovative approach uses a inductance-capacitance (LC) resonance method to improve sensor sensitivity. Additionally, it presents the design and implementation of an integrated oil condition sensor for simultaneous detection of wear debris and other lubricant properties.
Advancements in sensor technology, includes:
• Achieving three times sensitivity improvement with the LC resonance method.
• Development of an integrated oil condition sensor capable of measuring multiple properties simultaneously at high throughput.
• Utilization of artificial neural network (ANN) for accurate quantification of lubrication properties.
• Introduction of a real-time 3×3 wear debris sensor using synchronized sampling, significantly reducing data size and processing time while maintaining accuracy.
Unraveling Lighting Mysteries: High-Energy Radiation Exploration with VHF Interferometer
This application discusses a VHF broadband interferometer designed to explore unexplained lightning occurrences, focusing on high-energy radiation and multi-stroke positive cloud-to-ground flashes.
Challenge: Explore unexplained lightning occurrences, focusing on high-energy radiation and multi-stroke positive cloud-to-ground flashes. How the GaGe Digitizer was used: The research utilized a GaGe Razor Express 1604 digitizer, offering high-resolution data acquisition at a rapid sampling rate of 200MS/s. This digitizer facilitated the simultaneous recording of lightning events and high-energy radiation bursts, enabling detailed analysis.
Extraordinary Aspects of the Application: The results of this applicationpresents groundbreaking findings, including the detection of intense X-ray bursts from lightning leaders and their correlation with VHF pulses. The study highlights the presence of multiple high-energy radiation sources within lightning channels, shedding light on the complex nature of lightning phenomena. Additionally, the development of sophisticated instrumentation and data processing techniques represents a significant advancement in lightning research, promising deeper insights into these elusive natural events.
Whitepaper: What Defines Performance in High-Speed Digitizers

Introduction
Today’s advanced, PC-based digitizers for high-speed data acquisition are necessary for myriad applications – ranging from signal analysis, lidar, ultrasound imaging and non-destructive testing, to communications, particle physics, mass spectroscopy and more. This article highlights how digitizers are unique and describes the unique performance parameters engineers should use when selecting a high-speed digitizer.
Digitizers Cater to In-Process Signal Testing
While digitizers and Digital Storage Oscilloscopes (DSOs) both use Analog-to-Digital Converter (ADC) chips as their core electronics they are different tools. The DSO is optimized for the probing and visualization of signals that are typically encountered on an electronic engineer’s test bench during circuit development or first article approval of a PCB or cable. The signals are stored in the DSO acquisition memory and displayed on the DSO screen.
A digitizer can also display signals, but it is optimized for the acquisition of signals with high fidelity and at high repetition rates where the near real-time detection of small signal changes is critical. In Automated Test Equipment (ATE) for example, the digitizer typically acquires signals from an investigating probe, like an ultrasonic transducer or a photodiode. Further, unlike the unknown signals on a test bench, a digitizer typically acquires signals whose baseline characteristics are known but which experience small but critical deviations over time. Also, while digitizers are available as independent box instruments (like DSOs) most modern digitizers are highly integrated components of larger high-speed systems.
Widely Used Technology Platforms Help Digitizers Solve Complex Problems
Today’s highest-performance high-speed digitizers are installed on a shared electrical bus, such as a PXI or VXI bus within a dedicated instrument chassis or a PCI Express (PCIe) bus within most modern PCs. Modular digitizers may be integrated with other modular instruments under the control of a custom software application to create custom automated test equipment.
A 4-channel, 16-bit, 1000 MS/s digitizer card is shown in Figure 1. On the bottom of the card is the PCIe edge connector used to install it in a PCIe slot within the host PC. Once installed, the card’s SMA signal connectors emerge from the back of the PC chassis.

Figure 1. GaGe RazorMax PCI Express (PCIe) digitizer card with 4 input channels, 16-bit vertical resolution
Specifications Used to Differentiate Digitizers
Digitizer companies generally advertise three key specifications: channel count, vertical resolution and maximum sampling rate to indicate performance. In this section we will review these and describe why they are by themselves insufficient.
Channel Count
The channel count is simply the number of separate electrical signals that a digitizer can acquire. Generally, a digitizer is equipped with only a single acquisition sequencer, so that signals from all channels, while different, are all acquired in an identical fashion – namely, using the same sampling rate and trigger.
Vertical Resolution (Bit Depth)
Vertical resolution, specified in bits, reveals the number of discrete digital levels into which the vertical input voltage range of a digitizer is divided. This number of levels is equal to 2B, where B is the number of bits of resolution. For example, an 8-bit digitizer divides the vertical input range into 28 = 256 discrete levels. Accordingly, an 8-bit digitizer is unable to acquire vertical signal features that are smaller than one 256th of the input range. By contrast, a 16-bit digitizer divides the vertical input range into 65536 levels, which proportionately increases the sensitivity to signal features by a factor of 256.
Almost all DSOs use 8-bit ADCs, which are usually sufficient for visualizing signals. Smaller signals may be amplified, and larger signals may be attenuated using the DSO’s broad selection of vertical input.
Figure 2 shows how bit depth impacts signal clarity.

Fig.2. Figurative illustration of the relative accuracy of a 4-bit, an 8-bit digitizer ((typical of DSOs) and the 16-bit depth characteristic of the higher-end digitizers.
The value of high resolution is evident in applications where there are signals with high dynamic range—that is signals combing both high and low amplitude components. Examples of high dynamic range signals include exponential decay and ultrasonic, radar, or lidar signals that contain echoes from different-sized reflectors. High-amplitude components often inhibit excessive signal amplification, so high resolution is the only means of seeing low-amplitude echo and decay components.
Signal Deviation Detection Needs More Than Vertical Performance Signal Testing
In the process of converting an analog signal into a digital one, distortion can occur. Figures 3a and 3b show a pure sine wave, together with a sine wave that has been compromised by the addition of broadband signal noise and by signal distortion. Distortion is shown as attenuation near the input range limits, which is the typical precursor to signal clipping.

Fig.3a. Illustration of a pure sine wave (black) and one that has picked up noise (red).

Fig. 3b. Illustration of a pure sine wave (black) and one that has suffered distortion (red).
Consequently, the true measure of the vertical performance of a digitizer is not its nominal vertical resolution but the Effective Number of Bits (ENOB). ENOB is the effective resolution that is achievable in practice accounting for signal distortion and random noise introduced by the digitizer. A digitizer’s ENOB and other Dynamic Parameters are generally measured in the frequency domain.
In contrast to DSOs, dedicated digitizers — such as those on modular platforms like PCIe or PXIe — are usually optimized for the rapid acquisition and analysis of small changes in familiar signals. While providing lower maximum sampling rates, digitizers typically offer vertical resolutions of 12-, 14-, and 16-bits. The 16-bit RazorMax PCI Express (PCIe) digitizer in the example (Figure 1, above) exhibits the industry’s best ENOB of up to 12.1 bits.
Absolute vs Relative Accuracy
There is an important distinction between the absolute and relative accuracy of digitizers. The absolute accuracy of a digitizer describes how close its measured voltage values correspond to true absolute voltage reference standards. By contrast, relative accuracy specifies the fidelity of the shape of the acquired waveform with no reference to absolute reference standards. Using onboard calibration techniques, a high-speed digitizer may achieve absolute accuracies of an order of 0.1% of the full-scale input voltage range. In most digitizer applications, however, users are principally concerned with relative accuracy, which is specified by the Dynamic Parameters. The fidelity of a signal acquired by a digitizer device may be compromised by three distinct factors:
1. Addition of random noise by the digitizer to the acquired signal.
2. Distortion of the acquired signal by the digitizer.
3. Irregularities in uniformity of the time intervals between samples acquired by the digitizer arising from imperfections in the ADC clocking signal.
Maximum Sampling Rate
The sampling rate, usually measured in Mega Samples per second (MS/s), refers to the number of samples acquired by a digitizer per unit time. Nyquist sampling criterion requires the sampling rate to be at least twice the maximum frequency that a signal contains.
The Importance of Frequency Response
While the sampling rate is a key digitizer specification, an often-overlooked element of its time-domain performance is its frequency response curve. This curve is measured by acquiring a fixed amplitude sine wave with a digitizer and determining apparent measured sine wave amplitudes over a broad frequency range.
The frequency response curve for the RazorMax PCIe digitizer is shown in Figure 4. Frequency response curves function to show the analog input bandwidth, which is the frequency beyond which the digitizer attenuates a sine wave signal by 3dB or more. The bandwidth can be viewed as the -3dB roll-off frequency of the low-pass filter that a digitizer effectively presents to an input signal.
A common digitizer rule-of-thumb requirement is that the maximum frequency component within a signal acquired by a digitizer must be less than the digitizer’s bandwidth. This rule is often explained using the simplifying assumption that the digitizer behaves like a brick wall filter (more specifically a brick wall low-pass filter) that passes everything in the Pass Band below the bandwidth frequency (no attenuation) and that blocks everything in the Stop Band above the bandwidth frequency (infinite attenuation).
Such abrupt brick wall roll-off is not a good representation of the gradual roll-off of the curve of Figure 4. Consequently, determining the maximum usable signal frequency for a digitizer is a more nuanced decision than suggested by the common rule of thumb.
In the example of Figure 4, although a 200MHz signal is well below the 300MHz bandwidth of the digitizer, there is still an attenuation factor of -1dB, which corresponds to an amplitude decrease of about 11%. This significant attenuation may or may not be acceptable to the user, depending upon the application.

Fig. 4. Frequency response curve of the GaGe digitizer shown in Fig. 1. The vertical red line indicates the 600 MHz analog input bandwidth (or -3dB roll-off frequency) of the digitizer.
These measures avoid the creation of distorting signal reflections, which result in large oscillations within the frequency response curve.
Notwithstanding that the frequency response curve of Figure 4 is not a brick wall, it does indeed indicate a very good frequency response. The Pass Band shows a very flat response, and the attenuation is constant within 0.2dB up to a 100MHz signal frequency. As the curve rolls off, it shows only small residual oscillations of below 0.1dB. Poorly designed digitizers will exhibit large dB-order oscillations throughout their frequency response curves.
Design engineers must optimize the propagation of high-speed signals on a digitizer circuit board. Since signal wavelengths are of a similar scale to circuit board trace lengths, they must carefully control the electrical impedances and lengths of electrical circuit traces, stray capacitances, and other elements.
It is worth noting that the Nyquist sampling criterion employs and suffers from a similar simplification as the digitizer bandwidth rule-of-thumb. The Nyquist criterion requires 2X oversampling of the maximum signal frequency (or signal bandwidth) under the assumption that a signal has a brick wall spectrum, with no frequency components above the signal bandwidth frequency. A real signal will roll off more gently than a brick wall, so de-termining the required sampling rate becomes more nuanced. Often 5X or 10X over-sampling factors are employed to ensure that high-frequency signal components beyond the signal bandwidth are accurately acquired.
Conclusion
To maximize flatness in the Pass Band of the frequency response, engineers might maximize digitizer bandwidth so that higher signal frequencies could be acquired without attenuation. However, a digitizer’s bandwidth and ENOB are antipathetic –as one improves, the other degrades. Higher bandwidth reduces the low-pass filtering effect upon a signal. This lets through more high-frequency noise, which in turn degrades the ENOB.
Consequently, digitizer engineers must determine the optimal operating point that provides both sufficient ENOB performance and sufficient band-width. In addition to knowledge of its ENOB, consideration of its frequency response curve is paramount to the optimal selection of a digitizer for a given application.
Unlock RF Spectrum Secrets with the GaGe CSE1622 Digitizer
Summary: High-speed spectrum sensing is essential in many radar applications and can be achieved by modern digitizers paired with radios. The GaGe CSE1622, a gallium-germanium 16-bit, 200-MS/s PCIe digitizer, is utilized for this purpose. It rapidly captures 40-MHz-wide snapshots of the spectrum, which are filtered and down-converted by the SI-8614 Nanoceptor receiver. The data is then processed using LabVIEW virtual instruments (VIs), optimized for near-continuous capture rates and efficient real-time monitoring.
For optimal performance, a LabVIEW producer-consumer loop is employed. The producer loop quickly queues data captured from the digitizer; however, the consumer loop processes it slower using CUDA to perform multi-channel fast Fourier transform (FFT) computations. This setup is effective for wideband spectrum sensing and detecting nonlinear targets. Additionally, a higher resolution digitizer, the NI PXI-5922, is integrated to measure harmonics as low as -130 dBm, while maintaining the ability to capture higher power fundamental signals.
Explorations into using 24-bit high-fidelity audio cards as a low-cost, high-resolution digitizing solution for narrowband applications are also conducted, showcasing the versatility and efficiency of the GaGe CSE1622 digitizer in various spectrum monitoring tasks.
By leveraging the capabilities of the GaGe CSE1622 digitizer, researchers and engineers can achieve precise and efficient RF data capture, making it an invaluable tool in advanced spectrum analysis applications.
Read the full story on the Defense Technical Information Center website.
Education & Training
Check out our recent presentation of Understanding Electrical Safety Testers at the 2018 San Diego Test Equipment Symposium!